E1100 |
- Thaw Ground - quickly, easily and economically
- 1,100 - 2,200 sq. ft., standard
- up to 2,200 sq. ft. in 1/2 the time, with accessories
- Cure Concrete - in cold weather with confidence
- up to 2,200 sq. ft., standard
- up to 6,600 sq. ft. with accessories
- Prevent frost - large areas, very economically
- up to 3,300 sq. ft., standard
- up to 9,900 sq. ft. with accessories
- Heat workspace - dry heat and fuel efficient
- up to 180,000 cu. ft., with accessories
- Up to 115 hours run-time
- Engineered for reliable, trouble-free starts
- Easy to operate
- Economical
- Dependable
- Built Tundra Tough™
- 87% heater efficiency - highest in the industry
MOST User-Friendly Design
- Flip 2 switches
- Layout the hose
- Place poly and insulation
That's it! No complicated manifolds. No valves to open or close. No hoses to connect. Why do it the hard way? Ground Heaters' long hoses allow easy, flexible setup for all applications. It doesn't get any easier than a Ground Heater.
Specifications
Dimensions and capacities
| (no generator/with generator) | |
| Length - hitch assembly extended | 114" |
| Length - hitch assembly folded | 88" |
| Width | 65" |
| Height | 61" |
| Ground clearance | 10" |
| Appox. weight w/o fuel | 1,992 lbs/2,252 lbs |
| Appox. weight with fuel | 2,456 lbs/2,716 lbs |
| Fuel capacity | 72 US Gal |
| Heat Transfer Fluid | 50 US Gal |
| Pump, 265 US GPH positive displacement | 1 |
| Hose | 1 |
| Hose reel | 1 |
| Hose rewind | 120V AC, w/ 12V DC clutch |
| Circulation loop | 1 |
| Tires | ST185/80D13 |
| Hitch | 2" ball |
| Lifting bar | yes |
| Fork lift pockets | both sides and rear |
Performance
| Heater, gross output | 126,000 BTU/H |
| Heater, net output | 110,000 BTU/H |
| Heater efficiency | 87% |
| Temperature controller | digital |
| Fuel consumption at full load | 90/1.32 US GPH |
| Fuel requirement | winter blend diesel |
| Run time | up to 115 hours |
| Electrical requirement when not using on-board generator | 1 x 20 amps x 120 V AC |
| Normal operating temp | 100F° - 180F° |
| Normal hose operating pressure | 70-90 psi |
| HTF flow rate per loop | 265 US GPH |
| Thawing capacity (standard) | 1,100 - 2,200 sq ft |
| Thawing capacity (with accessories) | 2,200 - 3,300 sq ft |
| Curing capacity (standard) | 2,200 sq ft |
| Curing capacity (with accessories) | up to 6,600 sq ft |
| Frost prevention (standard) | up to 3,300 sq ft |
| Frost prevention (with accessories) | up to 9,900 sq ft |
| Air heat capacity (with accessories) | 180,000 cu ft |
| Performance monitoring light | yes |
Safety
| Tie downs (for transport) | 5 |
| Ground fault interrupt | yes |
| Main circuit breaker | 1 |
| Burner motor thermal protection | auto reset |
| Burner ignition | Electronic |
| High temperature shutdown | yes |
| No-flame shutdown | yes |
| Low fluid shutdown/warning light | yes |
| Vented closed loop circulation | yes |
| Hydronic heater operating pressure | 0 psi |
| Temperature gauges | 1 |
| Pressure gauges | 1 |
-
Granite City Tool carries a complete line of parts and accesssories and will help you configure a Ground Heater system to best suit your needs.